Preview: this page describes the next FireCAD release, planned for December 1, and the beta available now. For the current release, see Project Circuits Editor.
Watch the Video
Open the video in a new tab (Project Circuits Editor, 41 seconds).
Command
| Command | Description |
|---|---|
ATPROJECT_CIRCUITS_EDITOR |
Open the Project Circuits Editor |
Prerequisites
- A FireCAD project must be open
- The active drawing must be part of the project
Overview
The Project Circuits Editor shows every circuit in the project in one grid, so you can change circuit settings and limits for many circuits at once. Each circuit started as a copy of its circuit template; changes here apply to this project only.
Steps
- Click Project Circuits Editor... in the Circuits palette, or type
ATPROJECT_CIRCUITS_EDITOR - The editor opens with one row per circuit
- Type in Full Text Search to narrow the list, and select a circuit
- The lower grid, Circuit Types, shows each circuit type on the selected circuit with its Address Start Override, Quantity Limit and Quantity Threshhold %
- Edit the values you need. Bulk Edit Selected... applies one change to several selected circuits
- Click Apply to save, or Cancel to close without changing anything
- When changes are applied, device labels and wire path labels on the active drawing are updated
Columns
| Group | Columns |
|---|---|
| Identity | Panel, Card, Circuit Name, Origin Part Number, Description |
| Display | Device Properties, Locked, Hidden, Default Color, Detail Attribute Tag, Wirepath Label, Class, Cable |
| End of line | Show EOL, EOL Value String |
| Reports | Voltage Drop Report, Address Schedule, Speaker Schedule, Report Order |
| Addressing and wiring | Lock Addresses, T-Tap Wirefill |
| Current and power | Standby Current Max (A), Alarm Current Max (A), Use Current Limits On Battery Calc, Watt Limit, Current Max Threshold %, Watt Max Threshold % |
| Voltage drop | Starting Calculation Voltage, Min Voltage, Warning Voltage, Max Circuit Length (ft) |
| Battery | Battery Standby Multiplier, Battery Alarm Multiplier |
New in This Release
- Battery Standby Multiplier / Battery Alarm Multiplier: a per-circuit factor on the circuit's device current in the battery calculation, for circuits that run above the 24 V their devices are rated at (for example an IDNAC that boosts to 29 V in alarm). It changes the battery calculation only, never voltage drop. Leave it blank to use the circuit type's default
- Warning Voltage: a voltage between the start voltage and the minimum voltage. A circuit whose end voltage falls below it is highlighted as a warning on the voltage drop reports and in the Design Precheck, before it fails the minimum
Tips
- Limits and thresholds set here are what the Design Precheck checks the circuits against
- After you change circuit data, the Design Precheck lists any placed reports that are now out of date
- Use Bulk Edit Selected... to set the same value on many circuits at once rather than editing rows one by one
Related Commands
FireCAD is the industry-leading AutoCAD add-in for fire alarm system design — from circuit layout to wire routing to code-compliant reports.
Learn more and get started at getfirecad.com →
Inspect Point Integration — Fire alarm system device lists and bill of materials can be pushed directly from FireCAD into Inspect Point, eliminating manual data entry and ensuring every device is ready for inspection scheduling and ongoing asset management.
Learn more here →