Command
| Command | Description |
|---|---|
ATDELETE_ORPHANS |
Delete orphaned database records and update labels |
Ribbon: FireCAD > Validation > Purge Deleted Entities And Circuits
Prerequisites
- A FireCAD project must be open
Overview
Validates all segments and devices in the active drawing, deletes any orphaned database records (records that no longer correspond to drawing entities), and updates all labels.
Steps
- Type
ATDELETE_ORPHANSin the AutoCAD command line - FireCAD scans for orphaned records
- Orphaned records are deleted from the database
- All device and wirepath labels are updated
When to Use
- After deleting entities directly in AutoCAD (without using FireCAD commands)
- When the database contains records for entities that no longer exist in the drawing
- As a cleanup step after drawing modifications
Tips
- This performs segment and device validation before cleanup
- Labels refresh automatically after orphan deletion