Preview: this page describes the next FireCAD release, planned for December 1, and the beta available now. For the current release, see What Is the Best Way to Make a Project Revision or Backup the Project and Drawing?.
Overview
The FireCAD project file (.atpx) is tightly linked to its drawings (.dwg) and the other files in the project folder. AutoCAD's Save As on a drawing makes a new .dwg that is not connected to the project, so devices, circuits and connections do not carry over.
In this release, the best way to make a revision or a copy is Save Project As.
Save Project As (Recommended)
- With the project open, click Save Project As on the File panel of the FireCAD Tools tab (or type
ATSAVE_PROJECT_AS) - To make a revision, tick Save as a new revision and fill in Rev No., Date, By and Description. FireCAD adds the revision to the project's revision log, which fills the REVISIONS rows of the title block
- Enter the new project name and folder
- FireCAD saves the project, copies everything in the project folder to the new one, and opens the copy. The original stays as it was
The copy is a separate project: its drawings get new identities, and drawings named after the project are renamed to the new name. Edit it without affecting the original. See Save Project As (Preview).
Copying the Project Folder (Archiving)
To keep an archive snapshot without opening it, you can still copy the whole folder:
- Close the project in FireCAD so all files are released
- In Windows Explorer, copy the entire project folder and paste it alongside the original
- Rename the copied folder with a revision number or date, for example
MyProject_Rev2
Rename only the folder; leave the files inside it alone. For a copy you will keep working on, use Save Project As instead, so the copy is a separate project.
What Not to Do
-
Do not rename the
.dwgand then remove the drawing from the project and add it back. Removing a drawing clears the devices and connections that live on it, so adding it back gives you an empty drawing. If you have already renamed a.dwg, re-point the project at it with Add or Update Project Drawings instead - Do not use AutoCAD's Save As on the drawing to make a revision
Notes
- For incremental crash protection, see Embedded Drawing Backup & Recovery
- If your projects live in OneDrive, Dropbox or another synced folder, see Working From OneDrive, Dropbox, or Other Synced Folders. Sync can lock or damage the project file while FireCAD is writing to it
FireCAD is the industry-leading AutoCAD add-in for fire alarm system design — from circuit layout to wire routing to code-compliant reports.
Learn more and get started at getfirecad.com →
Inspect Point Integration — Fire alarm system device lists and bill of materials can be pushed directly from FireCAD into Inspect Point, eliminating manual data entry and ensuring every device is ready for inspection scheduling and ongoing asset management.
Learn more here →