Options & Configuration (Preview)

Preview: this page describes the next FireCAD release, planned for December 1, and the beta available now. For the current release, see Options & Configuration.

Command

Command Description
ATOPTIONS Open the Options Editor

Ribbon: FireCAD > Edit > Options

Prerequisites

  • A FireCAD project must be open

Overview

The Options Editor sets how FireCAD draws labels, builds reports, works with circuits and manages drawing elements. Settings apply to the current project, except the Design Assistant key and connection settings, which are stored for your Windows user.

The editor has eight tabs.


Text and Attributes

Setting Description
Device Attribute Text Height Height of device attribute text
Scale Device Attribute With Block Attribute text scales with the block
Apply Dimscale To Device Blocks Apply the drawing's dimension scale to device blocks
Wirepath Label Text Height Height of wire path label text
Riser Text Height / Riser Block Scale Text height and block scale in risers
Hide Wirepath Labels On Short Segments Segments shorter than this length get no label
Show Segment ID In Wirepath Labels Instead Of Wirefill Label segments with their ID; generate the Segment Label Schedule for reference
Mask Device Label Text / Mask Wirepath Label Text A background mask behind label text
Generate Line Types For Wirefill Instead Of Labels Draw wirefill into the wire's line type instead of as a label
Line Type Text Spacing Spacing of the text in those line types
Default Delimiter The character between label parts

Changed: Show Circuit Quantity In Wirepath Labels is gone; put [QTY] in the wire path label format instead. Report Text Height moved to the Reports tab.


Tools

Setting Description
ATPoly Fillet Radius (Units) Corner radius used by ATPOLY
Block Replacement: Alignment Mode, Rotation Mode, Scale How replacement blocks line up, rotate and scale. Scale 0 keeps the existing block's scale
Block Recognition: Recognize devices updated with Edit Block In Place New. FireCAD keeps recognizing devices whose blocks you edited in place

Layers

The layers FireCAD puts new elements on: Riser Layer, Report Layer, Wirepath Layer and Wirepath Label Layer. Leave a setting blank to use the active layer.


Circuits

Setting Description
Additional Wire Length Factor % Added to calculated wire lengths for slack and routing
Add Wire Label To Circuit Devices Without Complete Wirepaths Label devices even when their wire path is incomplete
Show Connection Status Icons In Model Space / Connection Status Icon Size Connection status icons on devices
Show Wirepath Status Icons In Model Space / Wirepath Status Icon Size Status icons on wire paths
Wirepath Intersection Tolerance How close a line must end to a device to count as connected to it
Add Virtual Wirepath Between Intersecting Devices Connect touching devices with a virtual wire path
Device Highlight Padding Space around a highlighted device
Device Coverage Transparency Transparency of coverage overlays
Copy Device Connections When Validating Copied Devices New. What Validate does when it finds devices you copied: Always copy their connections, Never copy, or Ask each time. Choose Ask each time to bring the prompt back after choosing Don't ask again

Reports

Rebuilt in this release. The report windows keep the same settings: a change here or in a report's own window is the same setting.

Group Settings
Voltage drop calculation (Panel Summary and Design Precheck) Point to point or Lump sum. The panel summary uses it, the Design Precheck judges voltage drop the same way, and the Design Assistant works to it
Display precision (digits) Length, Current, Voltage, Watts
Report text and layout Report Text Height, Symbol Scale Factor, Don't Include Unused Circuits, Add Reports and Risers to Current Drawing
Battery calculation (NFPA 72) Standby Time, Alarm Time, Derating Factor, Spare Capacity (extra capacity on top of derating: required Ah = load x derating x (1 + spare %)), Only Show Circuit Totals on Battery Calculation
For all reports Report Width Override (Drawing Units): one width for every report, or Auto. Settings each report also keeps show as partly filled (or (varies)) when the reports differ; leave them so to keep each report's own value, or set them to apply to every report

Removed: Report Column Width Factor, Include Existing Devices in Legend/BOM and Generate Legacy Reports.


Drawing

Drawing Units: the unit system of the current drawing.


Project

Setting Description
Project File Backup Quantity How many backup copies of the project file to keep. 0 turns backups off
Embed Project Backup In Drawings Embed a compressed project backup in each drawing on save, for recovery with ATRESTORE_FROM_DRAWING. See Embedded Drawing Backup & Recovery

Design Assistant (new)

Design preferences the assistant works to (voltage drop method, voltage margin, spare capacity, speaker voltage, mounting, ceiling height, standing instructions), your own Anthropic API key, the progress card, and the Claude Desktop connection. See Options: Design Assistant Tab (Preview).


Saving and Loading Settings

Button Action
Apply Save changes and update the drawing
Cancel Close without saving
Load Settings... Load settings from a saved .xml file
Save Settings As... Save the current settings to an .xml file to reuse in other projects
Reset Settings Reset settings to their defaults

When you click Apply, FireCAD saves the settings, updates device and wire path labels in the active drawing if label settings changed, and refreshes its cached values. A progress window shows the update; you can cancel the label update.

Tips

  • Use Save Settings As before experimenting, and Load Settings to go back
  • The battery settings (standby, alarm, derating, spare capacity) drive the battery calculation reports and the Design Precheck. Set them to your project's NFPA 72 requirements
  • Pick the voltage drop method once on the Reports tab; the panel summary, the Design Precheck and the Design Assistant all follow it

Related Articles


FireCAD is the industry-leading AutoCAD add-in for fire alarm system design — from circuit layout to wire routing to code-compliant reports.
Learn more and get started at getfirecad.com →

Inspect Point Integration — Fire alarm system device lists and bill of materials can be pushed directly from FireCAD into Inspect Point, eliminating manual data entry and ensuring every device is ready for inspection scheduling and ongoing asset management.
Learn more here →

Was this article helpful?